logo-blips04

Easy Software

In Swedish In English
Castle Rock Logo SNMPc

Easy SP - System Description

When starting Easy SP a synchronization performs with the map database in SNMPc. A polling process is added for every device in SNMPc that has an icon that corresponds to an icon on a Status Test in Easy SP. Devices are polled at regular intervals and status information is sent to SNMPc as internal traps. Every midnight a new synchronization performs with SNMPc to check if any devices should be added/removed from the polling processes.

If not all monitored objects in a Status Test is passed, an alarmNew-trap is sent to SNMPc along with status information. All polled devices/instances has uniq trapId´s, and a fired trap event is bound to the corresponding device in SNMPc.

An alarmCleared-trap is sent if there exist an alarm on a device/instance, and all monitored objects is passed in the Status Test.

A Status Tests can be of the type Single Instance or Table Instance. All data types (integers, counters and string values) can be monitored.

Easy SP - System Description

Figure 1. Flow Chart

Back